| Clàr 1 | Aonad | ZW32-12/630-20 | ZW32-12/630-25 | |
| Bholtaids reataichte | kV | 12 | ||
| Sruth reataichte | A | 630 1250 | ||
| Sruth briseadh geàrr-chuairte air a mheas | kA | 20 | 25 | |
| Sruth dùnaidh geàrr-chuairtichte air a mheas (buaic) | 50 | 63 | ||
| Sruth seasamh an aghaidh ìre as àirde | 50 | 63 | ||
| Sruth seasmhach geàrr-ùine air a mheas | 20 | 25 | ||
| Ùine leantainneach geàrr-chuairtichte air a mheas | s | 4 | ||
| Ìre insulation air a mheas | Bholtachd seasamh an aghaidh buille dealanaich (as àirde) | kV | Eadar-ìre, gu talamh 75, briseadh 85 | |
| 1min tricead cumhachd a’ seasamh an aghaidh bholtaids | Eadar-ìre, gu talamh 42, briseadh 48 | |||
| Sreath obrachaidh air a mheas | O-0.3s-CO-180s-CO (Obrachadh dealain) | |||
| Ùine briseadh sruth geàrr-chuairtichte air a mheas | Cearcallan | 30 | ||
| Beatha dealain | 10000 | |||
| Bholtaids obrachaidh reataichte (Coil fosglaidh is dùnaidh) | V | DC220,110,AC220 | ||
| Tiughas cruinnichte ceadaichte airson ceanglaichean a ghluasad agus a chàradh | mm | 3 | ||
| Sruth reataichte de thuiteam thar-shruthach | A | 5 | ||
| Co-mheas gnàthach an claochladair gnàthach (cunbhalach) | 200/5 400/5 630/5 | |||
| Astar fosglaidh conaltraidh | mm | 9±1 | ||
| Cuir fios gu cus stròc | 2⁺¹₋₀.₅ | |||
| Astar fosglaidh cuibheasach | m/s | 1.2±0.2 | ||
| Astar dùnaidh cuibheasach | 0.6±0.2 | |||
| Ùine fosglaidh | ms | 15~50 | ||
| Ùine dùnaidh | 25~80 | |||
| Ùine dùnadh turais | ≤2 | |||
| Sioncronachadh fosglaidh is dùnadh trì ìrean | ≤2 | |||
| An aghaidh DC gach cuairt ìre | mΩ | ≤80 | ||
| Motair stòraidh lùtha | Bholtaids reataichte | V | DC/AC 220 | |
| Cumhachd rangaichte | W | 70 | ||
| Ùine stòraidh lùtha | S | ≤8 | ||
| Cuideam | kg | 100 | ||
Diagram 1 Briseadh cuairte falamh àrd-bholtaids a-muigh ZW32-12
Diagram 2 ZW32-12(G) Briseadh-cuairt falamh àrd-bholtaids a-muigh
Diagram 3 ZW32-12(G) Meud stàlaidh briseadair cuairte falamh àrd-bholtaids a-muigh